Safety recommendations – H3C Technologies H3C S7500E Series Switches User Manual

Page 7

Advertising
background image

4

Power

module

Chassis

S7502E S7503E-

S

S7503E S7506

E

S7506E

-S

S7506E

(non-PoE)

S7506E

-V

S7510

E

PSR1400-A —

z

z

z

z

z

z

PSR1400-D —

z

z

z

z

z

z

PSR2800-A
CV

— — z

z

z

z

z

PSR6000-A
CV

— — z

z

z

z

z

NOTE:

"z" indicates that the power module can be directly installed on the chassis.

"{" indicates that you must first install a power module adapter on the chassis and then install the
power module on the power module adapter.

"—" indicates that the power module cannot be installed on the chassis.

Safety recommendations

To avoid equipment damage or bodily injury caused by improper use, read the following safety

recommendations before installation. Note that the recommendations do not cover every possible
hazardous condition.

To prevent ESD damage, always wear an ESD wrist strap and make sure it is reliably grounded
before you touch the switch, cards, or PCB.

Do not install the switch, FRUs, or power cords when the switch is powered on.

To avoid equipment damage or bodily injury, make sure the switch is reliably grounded before
powering on the switch.

To ensure good ventilation, install a blank filler panel in an unused slot.