11

Figure 5 Connect the grounding cable to the grounding hole of the RPS
unit

(1)

(2)

(3)

(4)

(5)

(1) Rear panel of the RPS unit

(2) Grounding screw

(3) OT terminal

(4) Grounding cable

(5) Grounding hole

Follow these steps to attach the other end of the grounding cable to the
grounding strip:

Step1

Peel 5 mm (0.20 in) of insulation sheath by using a wire stripper,
and insert the bare metal part through the black insulation
covering into the end of the OT terminal.

Step2

Secure the metal part of the cable to the OT terminal with a
crimper, cover the joint with the insulation covering.

Step3

Connect the OT terminal to the grounding pole of the
grounding strip, and fasten it with a hex nut.

Advertising