Installing an MPU and a switching fabric module

Installing an RSE-X2 MPU

CAUTION:

The RUN LED flashes fast when the MPU is starting up. Do not install or remove the MPU during this period.
Otherwise, hardware might be damaged.

Before the installation, make sure the ejector levers of the MPU are outwards.
The Slot 4 of the SR6616-X is not provided with a filler panel.
To install an RSE-X2 MPU:

1.

Face the front of the router and locate the slot to be used.

2.

Loosen the captive screws with a Phillips screwdriver to remove the filler panel from the slot.
Keep the removed filler panel for future use.
Skip this step if you install the MPU to the Slot 4 of an SR6616-X router.

3.

Insert the MPU slowly along the slide rails until it makes close contact with the backplane, and then
push the ejector levers inward to lock the MPU in position.

4.

Use a Phillips screwdriver to fasten the captive screws on the two sides of the MPU.

For the MPU LED description, see "

MPU and switching fabric module LEDs

."