Using the 2000NET GUI

Frame Heath Reporting

The reporting of Slot Fault, Signal Loss, and Reference Loss for the media
module can be enabled or disabled to the external Frame Health alarm con-
nector, J103, on the rear of the Kameleon frame. Selecting or deselect the
corresponding checkbox to enable or disable alarm reporting.

Hardware Switch Controls

This section is a read-only status report of 2000NET module switch settings
for Module Status Reporting and Asynchronous Status Reporting. These
functions must be enabled for the following Slot SNMP Trap Reports to
function. Refer to

Alarms and SNMP Monitoring on page 19

.

Slot SNMP Trap Reports

This section is displayed only when the SNMP Agent software has been
installed on the 2000NET module in the same frame as the media module.

The following SNMP trap reports are provided for applicable 2000 and
Kameleon Series media modules:

Slot Fault (Alarm)

Module Removed (Warning)

Signal Loss (Warning)

Reference Loss (Warning)

Enable (select the checkbox) or disable (deselect the checkbox) for the
desired SNMP monitoring.

Note

SNMP functionality varies on media modules depending on the type of
module and its software version.