Grass Valley 2000NET v3.2.2 User Manual
Page 40
40
2000NET Instruction Manual
Using the 2000NET GUI
Frame Heath Reporting
The reporting of Slot Fault, Signal Loss, and Reference Loss for the media
module can be enabled or disabled to the external Frame Health alarm con-
nector, J103, on the rear of the Kameleon frame. Selecting or deselect the
corresponding checkbox to enable or disable alarm reporting.
Hardware Switch Controls
This section is a read-only status report of 2000NET module switch settings
for Module Status Reporting and Asynchronous Status Reporting. These
functions must be enabled for the following Slot SNMP Trap Reports to
function. Refer to
Alarms and SNMP Monitoring on page 19
.
Slot SNMP Trap Reports
This section is displayed only when the SNMP Agent software has been
installed on the 2000NET module in the same frame as the media module.
The following SNMP trap reports are provided for applicable 2000 and
Kameleon Series media modules:
•
Slot Fault (Alarm)
•
Module Removed (Warning)
•
Signal Loss (Warning)
•
Reference Loss (Warning)
Enable (select the checkbox) or disable (deselect the checkbox) for the
desired SNMP monitoring.
Note
SNMP functionality varies on media modules depending on the type of
module and its software version.