Power up, Operation indicator leds – Grass Valley 2020DAC D-To-A User Manual

Page 12

Advertising
background image

6

2020DAC Instruction Manual

2020DAC 4-Channel Audio Digital to Analog Converter

Power Up

The front LED indicators and configuration switches are illustrated in

Figure 6

. Upon power-up, the green PWR LED should light and the yellow

CONF LED should illuminate for the duration of module initialization.

Operation Indicator LEDs

With factory default configuration and a valid input signal connected, the
green PWR LED should be on and the yellow REM OVER LED should be
off (refer to

Table 4 on page 7

to see a complete list of possible operating

conditions and the resulting indicator status).

Audio input presence is indicated for both Channel 1/2 and Channel 3/4
by the 32, 44.1, or 48 green LEDs which indicate the corresponding input
signal sample rate has been detected. Each channel also has a yellow EMPH
LED to indicate when de-emphasis is being applied. The yellow REM
OVER LED indicates that the on-board configuration jumpers and switch
settings are being overridden by the remote control settings.

Figure 6. LEDs and Configuration Switches

16-position
Rotary switch for
Channel 1/2 Mode

32 – Green LED on indicates active sample rate on Channel 1/2

PWR – Green diagnostic LED on indicates power OK

FAULT – Red diagnostic LED is off during normal operation

Ejector Tab

COMM – Yellow LED on during remote control communication

CONF – Yellow LED on when module is initializing or processing control data

44.1 – Green LED on indicates active sample rate on Channel 1/2

48 – Green LED on indicates active sample rate on Channel 1/2

GND – Digital ground

EMPH – Yellow LED on indicates module is performing de-emphasis on Channel 1/2

8023_01r1

0

1

2

3 4

5 6 7

8

9

A

B

CD

E

F

0

1

2

3 4

5 6 7

8

9

A

B

CD

E

F

16-position
Rotary switch for
Channel 3/4 Mode

32 – Green LED on indicates active sample rate on Channel 3/4

44.1 – Green LED on indicates active sample rate on Channel 3/4

48 – Green LED on indicates active sample rate on Channel 3/4

EMPH – Yellow LED on indicates module is performing de-emphasis on Channel 3/4

REM OVER – Yellow LED on indicates local settings/jumpers overridden by remote control

CH1/2

CH3/4

Advertising