Configuration, Local configuration, Remote configuration – Grass Valley 8943RDA User Manual

Page 62

Advertising
background image

62

8943RDA/-D/-DFR — Instruction Manual

Configuration

Configuration

The 8943RDA-DFR can be configured using the front edge onboard con-
trols or using the remote controls available with a web browser or a net-
worked Newton Control Panel.

The Input Operating mode for all available inputs, Coax inputs J10 and J8,
and Fiber RX 1 input (with Dual Receiver SFP option installed) and Fiber
RX 2 (with Dual Receiver or Transceiver SFP option installed) must be con-
figured. All inputs can be active at the same time.

Each of the four possible input channels (Coax 10, Coax 8, Fiber RX 1, and
Fiber RX 2) can be assigned (mapped) to any one output pair or fiber output
as desired. The number of outputs depends on the type of SFP fiber optic
submodule installed. Outputs include Coax pairs J1/J2, J3/J4, J5/J6 and J7
(always active) and Fiber TX 1 (with Dual Transmitter or Transceiver option
installed) or Fiber TX 2 (with Dual Transmitter SFP option installed).

Note

Fiber optic Tx1 and Tx2 outputs must be enabled by setting Jumper J13 on
the module circuit board. Refer to

Figure 15 on page 33

.

Local Configuration

For Local configuration, follow the summary of instructions given in

Local

Onboard Configuration on page 33

for using the front edge onboard switches

for configuration.

Remote Configuration

Remote configuration methods are summarized in

Remote Configuration on

page 38

.

For the 8943RDA-DFR module, each of the available web pages with and
without the SFP fiber optic options are shown on the following pages:

Status (

page 63

)

I/O Config (

page 68

)

Settings (

page 73

)

Slot Config (

page 78

)

Use