Tdm sub-module leds – Grass Valley Concerto Routing Matrix v.1.8.1 User Manual

Page 159

Advertising
background image

Concerto — Installation and Service Manual

159

Troubleshooting

TDM sub-module LEDs

The location of the LEDs on the TDM sub-module is shown in

Figure 90

.

See

Table 60

for LED usage.

Figure 90. TDM sub-module LEDs Location

Table 60. TDM sub-module LEDs

LEDs

Label

Indication

Condition

ACTIVE

(green)

On

Active (Master) mode

Off

Standby (Redundant) mode

a

a

Redundant mode is not supported.

DONE

(green)

On

Normal

Off

Problem

b

b

Verify the TDM is properly installed onto its host module and the host module is properly seated.

TRANS 1 LOCK

(green)

On

Locked to reference and transmitting signals to OUT 1

Off

Problem

c

c

If the Done LED is lit and this is off then there is a cabling problem, verify the cabling.

TRANS 2 LOCK

(green)

On

Locked to reference and transmitting signals to OUT 2

Off

Problem

c

REC 1 LOCK

(green)

On

Locked to reference and receiving signals from IN 1

Off

Problem

c

REC 2 LOCK

(green)

On

Locked to reference and receiving signals from IN 2

Off

Problem

c

8138_04_143r1

ACTIVE

DONE

TRANS 1

LOCK

TRANS 2

LOCK

REC1

LOCK

REC2

LOCK

ACTIVE

DONE

TRANS 1

LOCK

TRANS 2

LOCK

REC1

LOCK

REC2

LOCK

TDM Submodule
rear view

TDM Submodule
front view

Location of

LEDs

Location of

LEDs

Audio Module

TDM Submodule is mounted

under Audio Module