Reference tables, Physical level table, Appendix b — reference tables – Grass Valley Concerto Routing Matrix v.1.8.1 User Manual

Page 169: Appendix b-reference tables, Appendix, Concerto — installation and service manual 169, Controller module

Advertising
background image

Concerto — Installation and Service Manual

169

Appendix

B

Reference Tables

Physical Level Table

Table 69

is the complete table for setting Physical Levels on the DIP Switch

banks S2, S4, S7, and S9 on the

CRS-MC-C2

Controller module.

Note

Physical Level 0 is not used.

Table 69. Physical Level Settings for DIP Switches S2, S4, S7, and S9

Physical

Level

DIP Switch Position Number

1

2

3

4

5

6

7

1

ON

OFF

OFF

OFF

OFF

OFF

OFF

2

OFF

ON

OFF

OFF

OFF

OFF

OFF

3

ON

ON

OFF

OFF

OFF

OFF

OFF

4

OFF

OFF

ON

OFF

OFF

OFF

OFF

5

ON

OFF

ON

OFF

OFF

OFF

OFF

6

OFF

ON

ON

OFF

OFF

OFF

OFF

7

ON

ON

ON

OFF

OFF

OFF

OFF

8

OFF

OFF

OFF

ON

OFF

OFF

OFF

9

ON

OFF

OFF

ON

OFF

OFF

OFF

10

OFF

ON

OFF

ON

OFF

OFF

OFF

11

ON

ON

OFF

ON

OFF

OFF

OFF

12

OFF

OFF

ON

ON

OFF

OFF

OFF

13

ON

OFF

ON

ON

OFF

OFF

OFF

14

OFF

ON

ON

ON

OFF

OFF

OFF

15

ON

ON

ON

ON

OFF

OFF

OFF

16

OFF

OFF

OFF

OFF

ON

OFF

OFF

17

ON

OFF

OFF

OFF

ON

OFF

OFF

18

OFF

ON

OFF

OFF

ON

OFF

OFF

19

ON

ON

OFF

OFF

ON

OFF

OFF

20

OFF

OFF

ON

OFF

ON

OFF

OFF

21

ON

OFF

ON

OFF

ON

OFF

OFF

22

OFF

ON

ON

OFF

ON

OFF

OFF

23

ON

ON

ON

OFF

ON

OFF

OFF

CLEAR MEM

S2

S5

S11

S10

S13

S12

S4

S3

S9

S8

S7

A_LEVEL

B_LEVEL

A_OPTION

S

C_LEVEL

D_LEVEL

B_OPTION

S

C_OPTION

S

D_OPTION

S

MODE/IN

S

EL

S

11

S

12

S

13

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

M A T R I X MAP

C O N F I G