GUIDE TO INSTALLATION AND OPERATION

68 | LGK-3901/DSK-3901

The panel is organized into the following columns:

• Status/Name

• Card

LED

• Overall

alarm

• GSM

contribution

• Log

events

6.4.13.1 Status/Name


This contains an expandable tree view of all alarms reported by the LGK-3901/DSK-3901 card. Each alarm name
includes an icon that shows its current status.

Each of the individual alarms listed in the Status/Name column can contribute to bulk alarms in the other columns.

6.4.13.2 Card LED


The Card LED column contains pull-down lists that allow the operator to set the level of contribution of each individual
alarm to the card-edge status LED alarm (see section 6.2) for the LGK-3901/DSK-3901.

6.4.13.3 Overall Alarm


This Overall Alarm column contains pulldown lists that allow the operator to set the level of contribution of each
individual alarm to the overall alarm for the LGK-3901/DSK-3901.

The overall alarm is shown in the upper left corner of the iControl panel and also appears at the bottom of the
Status/Name column.

6.4.13.4 GSM Contribution


The GSM Contribution column contains pulldown lists that allow the operator to set the level of contribution of each
individual alarm to the GSM alarm status associated with the LGK-3901/DSK-3901.

GSM is a dynamic register of all iControl system alarms, and is also an alarm provider for external applications. The
possible values for this contribution are related to the Overall alarm contribution:

• If the Overall alarm contribution is selected as Disabled, the GSM alarm contribution can be set to any

available value

• If the Overall alarm contribution is selected as any level other than Disabled, the GSM contribution is forced to

follow the Overall Alarm.