Grass Valley UIM v.2.1.1 User Manual

Page 105

Advertising
background image

February 5, 2008

UIM Instruction Manual

105

Configure CVFS Client software on the UIM-SAN-FCIP

• Select

Allow Diskless Mount

. This setting is required on both redundant FSM and

single FSM systems.

• Select

Fast Failover Detection

. This setting takes effect only on redundant FSM

systems. For consistency, you should select it on single FSM systems as well, as it
has no adverse effect.

• Select

Delay Atime Updates

. This setting improves the ability of transfer streams to

continue during an automatic system recovery event.

Leave the rest of at their default settings.

8. Click

OK

and

Yes

to save settings and close the application.

9. When prompted, re-start the UIM-SAN-FCIP.

10. Continue with the next procedure

“Perform miscellaneous system settings”

.