Other command specifics, D other, Command specifics – Grass Valley Switcher Products User Manual

Page 122

Advertising
background image

122

Switcher Products — Protocols Manual

Section 4 — DPM CPL Protocol

Other Command Specifics

The bulk of the communications used for the switcher/DPM interface is via
parametric interchange, as indicated in Appendix B. This section tabulates
other commands used by the switcher/DPM interface.

Currently, the only other communications is the exchange of an on line
event while communications are initiated. The DPM must transmit an on-

Table 114. Switcher/DPM Parameters

Parameter Name

ID

Device

Type/Range

Switcher

DPM

PID_FRONT_VIDEO_SOURCE_LIST

810

Channel bit map:
0x00000001 = Chan 1
0x00000002 = Chan 2
0x00000004 = Chan 3
0x00000008 = Chan 4
0x00000010 = Chan 5
0x00000020 = Chan 6
0x00000040 = Chan 7
0x00000080 = Chan 8
(typically ORed to address
several channels at once)

8 bytes
Chan 1 first
1 - 48
all 8 bytes must be sent
even if bit not set in
device map

Rx SET

Tx SET

PID_VIDEO_BACK_SOURCE_LIST

813

PID_FRONT_KEY_SOURCE_LIST

811

PID_BACK_KEY_SOURCE_LIST

814

PID_FRONT_BACK_SELECT_LIST

816

8 bytes (as above)
Chan 1 first
0 = front
1 = back

PID_VIDEO_SOURCE

2642

Channel bit map:
0x00010000 = Chan 1
0x00020000 = Chan 2
0x00040000 = Chan 3
0x00080000 = Chan 4
0x00100000 = Chan 5
0x00200000 = Chan 6
0x00400000 = Chan 7
0x00800000 = Chan 8
ORed with
Back side bit map:
0x00000001 = Chan 1
0x00000002 = Chan 2
0x00000004 = Chan 3
0x00000008 = Chan 4
0x00000010 = Chan 5
0x00000020 = Chan 6
0x00000040 = Chan 7
0x00000080 = Chan 8
(refer to text)

short
1 - 48

Tx SET

Rx SET

PID_KEY_SOURCE

2643

PID_VIDEO_ON_SCREEN

819

Channel bit map
(refer to source list parameters
above)

1 boolean
(applies to all channels
specified in device field)

Tx SUB
Rx ISSUE

Rx SUB
Tx ISSUE

PID_KEY_ON_SCREEN

820

PID_VIDEO_ON_AIR (optional)

819

Rx SUB
Tx ISSUE

Tx SUB
Rx ISSUE

PID_KEY_ON_AIR (optional)

820

PID_CURRENT_EFFECT

886

0 = Effect Manager

short
any value

Tx SUB

Rx ISSUE
Tx SET

Rx SUB
Tx ISSUE
Rx SET

PID_EFFECT_POSITION

875

0 = Effect Manager

s15.16 in frames

Tx SET

Rx SET

PID_SYSTEM_NAME

917

0 = Effect Manager

exactly 16 chars

no terminating null
pad with spaces

Tx SUB

Rx ISSUE

Rx SUB-I
Tx ISSUE

Rx SUB
Tx ISSUE
optional:
Tx SUB-I
Rx ISSUE

PID_ETHERNET_ADDRESS

(optional - refer to Activity Check description)

3047

0 = Effect Manager

long
(refer to text)

Tx SUB-I

Rx ISSUE

Rx SUB-I
Tx ISSUE

Advertising