Appendix A Specifications

A-10

PDR100 Installation

Environmental Characteristics

Mechanical Characteristics

Table A-15. Environmental Characteristics

Characteristics

Description

Operating Temperature

Requirement:

5

°

to 40

°

C (+41

°

to 122

°

F)

Storage Temperature

Requirement:

-40

°

to 65

°

C (-40

°

to 149

°

F)

Operating Altitude

Requirement:

To 15,000 feet (4572 meters)

Supplemental Data:IEC 950 compliant to 2000 meters

Storage Altitude

Requirement:

To 50,000 feet (15,240 meters)

Vibration

Requirement:

Military Specification: Mil-T-28800D, Class 6
(Non-Operating Only)

Mechanical Shock

Military Specification: Mil-T-28800D, Class 6 (Non-Operating Only)

Transportation

Requirement:

Qualified under NSTA Test Procedure 1A, Category II
(24 inch drop)

Equipment Type

Supplemental Data:Information Technology

Equipment Class

Supplemental Data:Class I

Installation Category

Requirement:

Category 2 Indoor use only

Pollution Degree

Requirement:

Level 2 operating environment

Humidity

Requirement:

Operating 20% - 80%
Non-Operating 8% - 90%
Transportation 5% - 95%
Maximum Wet Bulb Temperature 26

°

Supplemental Data:Do not operate with visible moisture on the circuit

boards

Table A-16. Mechanical Characteristics

Characteristic

Description

Dimensions

Requirement:

Height:

8.750 inches (22.225 centimeters)

Width:

19.000 inches (48.260 centimeters)

Depth:

23.500 inches (59.690 centimeters)

Weight

Requirement:

Net:

70 pounds (31.751 kilograms)

Shipping:

85 pounds (38.555 kilograms)