Planning Guide

74

Planning and Installation Manual

SMS Control

In this arrangement the router is under SMS control via a LAN connec-

tion. The PC is used to configure the SMS and is also available for

Broadlinx or SNMP monitoring. See

Figure 36

.

Figure 36. SMS connections to Trinix.

If you plan on using a secondary NR-33000 board another Ethernet

cable must be connected from the “NIC B” jack to the network

switch.
If the Trinix LAN is connected to the Internet the connection should

be made through a firewall.

NIC A

connector

Ethernet switch

NIC B

connector

Trinix

MCPU frame

7000 SMS

PC