Temporary Safety Jumpers

For the highest level of safety, the Estate Swing systems are set up with Normally Closed safety
terminals. This means that in order for the door opener to move these terminals must be closed
either through a safety device (recommended) or with jumpers. Temporary safety jumpers are
provided in the control box hardware bag for jumping these terminals to common (COM) during
the set-up process.
It is recommended not to use any accessories until setup and programming are complete.

NOTE: If not using safety devices the temporary safety jumper must remain in. In order for
the door operator to move, all three safety terminal lights (STOP, FSW CL, FSW OP) must
be lit.


If not using limit switches, and ONLY if NOT using limit switches, you must jump be-
tween the limit switch terminals (FCC1, FCA1, FCC2, FCA2) and limit common
(COMF).

Other Possible Jumpers Needed

ONLY IF NOT USING
LIMIT SWITCHES

4.5