Control Board LED Lights

- The control board LED lights are located above their respec-

tive terminals that they represent. (With exception of ALIM, power supply light, which is located
below the power terminals in the upper left corner.) The LED lights are a quick way of verifying
necessary connections are made. Below is a chart of their interpretations.

LED Lights & Operational Displays

LED

ON

OFF

ALIM

Powers supply by transformer

Power supply by battery or no power

FCC 1

Motor 1 closing limit switch - not tripped

Motor 1 closing limit switch - tripped

FCA 1

Motor 1 opening limit switch - not tripped Motor 1 opening limit switch - tripped

FCC 2

Motor 2 closing limit switch - not tripped

Motor 2 closing limit switch - tripped

FCA2

Motor 2 opening limit switch - not tripped Motor 2 opening limit switch - tripped

STOP

Stop command - not activated

Stop command - activated

FSW CL

Closing safety device - not tripped

Closing safety device - tripped

FSW OP

Opening safety device - not tripped

Opening safety device - tripped

During idle for single door openers, all should be on except FCC 2 and FCA 2.
During idle for dual door openers, all LED lights should be on.

If not using safety devices , you must jump STOP, FSW CL and FSW OP to COM in order
for the door opener to function.

Standard Operation Display

- This is when the door opener is not in parameter setting

mode or programming mode. LED displays DS1 and DS2 will show the following:

Door Status

Door At Rest in Closed Position

Door Opening or Door Open when Auto Close is OFF

Door open in pause status
(Only with automatic re-close enabled - Parameter c)

Door Closing