Operating Parameters Chart

Minimum Force

Medium-low Force

Medium-high Force

High Force

This parameter adjusts the sensitivity of the
electronic clutch system. The electronic clutch
system controls the anti-crushing auto-reverse
feature when a door in motion makes contact
with an obstacle.

1.5 Second Offset

3 Second Offset

6 Second Offset

10 Second Offset

This determines how long the second leaf will
pause before moving to allow the first leaf to
separate and avoid obstructing on the other
leaf.
If using a Single door opener system, the set-
ting will not affect your door.

Disabled

Enabled

This parameter turns auto-close on or off. The
pause time for the auto-close is set during
movement programming.

OPEN
A

Opens/Closes/Opens...

Opens/Stops/Closes/Stops...

This parameter determines what an OPEN A
terminal command will result in. d1 is recom-
mended for safety.

Disabled

Enabled

This parameter is for use with multiple door
users. If enabled, when the door is opening it
can not be reversed by another open signal.

FORCE

DELAY

AUTO-

RECLOSE

CONDO

Disabled

Enabled

OVER-
PUSH

This parameter is for use with electric door
locks. The door will briefly push further closed
before opening to allow the lock to release.

Flashing Lamp

90 Second Courtesy Light

LAMP

This parameter is to determine between a
flashing or steady lamp. If not using a lamp the
setting will not affect your door.

Continued on following page.