Estate Swing E-SC 1600 User Manual

Page 23

Advertising
background image

20% of total arch

10% of total arch

SOFT

START/

STOP

This parameter determines when the door will
begin to slow down near the end of opening
and closing cycle.

Low

High

SOFT

SPEED

This parameter determines how fast the door
will move during the soft start/stop. If using
positive stops this parameter must be on 0.

No Limit Switch

Limit Switch

LIMIT

SWITCH

In this parameter you MUST specify whether
you are using limit switches or not for proper
function of your door.

Single Leaf Door

Dual Leaf Door

SINGLE

OR DUAL

In this parameter you MUST specify whether
you are using single door (one leaf - one
motor) or dual door (two leaves - two motors).

After programming your last parameter you may now move on to
programming your door run time. Press P2 one more time to exit this
mode. Door movement instructions begin on the next page.

5.3