17.4.1 Wiring of the EMERGENCY STOP Interface (Basic Circuit Diagram)

-24V

X44/2

24V

outputs

INPUT:

x44/3

Acknowledgement

“Control Ready

for Operation”

Int.

STOP

Machine Tool

OUTPUT:

Limit Switch

“Control Ready

LE 4071415

for Operation”

17.4.2 EMERGENCY STOP Flow Diagram: TNC 407

1

I

3

I

Time

1

4

Remarks

Error Message

POWER INTERRUPTED

Waiting

for control voltage

After switching off the output “Control Ready
for Operation”, the “Acknowledgement Control

Ready for Operation” must be switched off

within 146 ms; otherwise a blinking error

message is generated.

If the acknowledgement is switched off during

operation, the error message is displayed.