Analog outputs, 1 specifications, Checking the analog outputs – HEIDENHAIN TNC 407 (243 020) Service Manual User Manual

Page 90: 2 checking the analog outputs

Advertising
background image

SERVICE MANUAL TNC

Issue:

01.09.1995

Page

74

16. Analog Outputs

16.1 Specifications

6 outputs:

Load capacity:

Voltage range:

Resolution

2, 3, 4, 5, and S

Machine Parameters for the Analog Outputs

Analog Output

MP

Entry Value

mint 5

X

120.0 0 = output 1

Y

120.1 1 = output 2
120.2 2 = output 3

IV

120.3 3 = output 4

V

120.4 5 = output 5

TNC 407

TNC 415

14 bits 16 384 steps

16 bits 65 536 steps

Smallest step

=

16.2 Checking the Analog Outputs

Proportionally to the traversing speed, the control generates an analog

OV (axis standstill) to

(rapid traverse). The easiest way to determine this voltage is to connect the test adaptor directly to the logic
unit or to the connecting terminals of the servo-amplifier and to measure with a multimeter.

If however, the axis does not move due to a defect, and you want to test whether the error is inside or outside

the control, the following steps are recommended:

Switch off the main switch of the machine tool.
Connect the test adaptor to the connector X8 (nom. value output) of the LE and connect a multimeter to the

test adaptor sockets for the defective axis If no test adaptor is available, connect a multimeter directly to the

nominal value output of the servo-amplifier.

Switch on the main switch and the control voltage.
Switch the position display to LAG (servo

sec. 16.3).

Check or adjust the following machine parameters. (If you alter the machine parameters, note down the

original values and enter them again after finishing the test.)

MP Entry Function

Original Value

Value

1720

100

Servo-lag monitoring EMERGENCY STOP

1140

Movement monitoring

Traverse the reference points that need to be traversed before those of the defective axis.
Turn the override potentiometer of the keyboard unit completely to the left and start reference point traverse

for the defective axis.

Check the axis enable for the defective axis at the servo amplifier.
Check the screen display

(control ready for operation) must be switched on, the

of the feed display must be lit normally the

display is inverse, the feed enable is missing), and the symbol for “Axis not in the Position Loop” (e.g.
should not follow the position display.

Turn the override potentiometer slowly to the right and turn it back left before the servo lag display reaches

the limit of the position monitoring

Advertising