2.4.1 General RS-485 bus installation

The EKB-500 keyboard uses a RS-485 simplex wiring; the signal is transferred via a single twisted pair line.
CAT5 network cable is recommended, UTP version (unshielded) is sufficient for normal applications. A

shielded cable should be used if the installed cables are expected to be highly susceptible to interference.
The number of devices installed in one bus is limited to 32, and the maximum cable length is 3,900 feet.

Both of these can be expanded using a signal distributor EverFocus Model EDA997A (see below).


Both the first and the last device in series should be terminated with 120 Ohm resistance in order to

minimize line reflections.

RS-485 bus serial wiring

Cable length from box to device („Stubs“) has to be limited to 2m using connector boxes.

RS-485 bus serial wiring with connector boxes and connection cable


Direct RS-485 bus star wiring is not supported unless using an EverFocus Model EDA997A (see below).

Improper RS-485 bus star wiring


An EDA997A RS-485 signal distributor may be used to use a star wiring configuration.


Star wiring with RS-485 signal distributor