5 alarm & event setting, 1 alarm, Alarm & event setting – EverFocus ENDEAVOR 22HH1144 User Manual

Page 68: Alarm

Advertising
background image

59

4.5 ALARM & EVENT SETTING

Figure 4-10

is a screenshot of the ALARM & EVENT SETTING MENU. This menu will guide you through

alarm and event setup.

Figure 4-10 Alarm & Event Menu - Alarm

4.5.1 Alarm

Alarm: Select the alarm input trigger connection number from 1 to 16.
Enable: Check box to enable response to that alarm trigger.
Log: Check box to record these alarm events in the log.
Pre-alarm Record: Check box to start copying recorded video to the hard disk from 5 seconds before the

alarm event. (Pre-alarm recording rate will follow the “Normal” frame rate setting)
Buzzer:
Check this box to enable the buzzer when an alarm occurs.
Main Monitor: Main monitor display options when a motion occurs.

No change: No change on the main monitor display.
Full screen: A full screen of the active camera will display on main monitor.

Record: Select which camera(s) will start recording in response to this alarm event.
Email Notify:
Check box to enable email notification when an alarm occurs. Email operation requires that

valid email settings have been entered in the Network Setting/Email setup screen. (See Section 4.6.2 Email
for more information.)

Advertising