381

14.4 T

est Run

Executing a test run

If the central tool file is active, a tool table must be active (status S) to
conduct a test run. Select a tool table via the file manager (PGM MGT)
in the Test Run mode of operation.

With the BLANK IN WORK SPACE function, you activate work space
monitoring for the test run, see "Showing the Blank in the Working
Space", page 377.

U

Select the Test Run operating mode

U

Call the file manager with the PGM MGT key and

select the file you wish to test, or

U

Go to the program beginning: Select line 0 with the

GOTO key and confirm your entry with the ENT key.

The TNC then displays the following soft keys:

You can interrupt the test run and continue it again at any point—even
within a fixed cycle. In order to continue the test, the following actions
must not be performed:

„

Selecting another block with the arrow keys or the GOTO key

„

Making changes to the program

„

Switching the operating mode

„

Selecting a new program

Functions

Soft key

Reset the blank form and test the entire program

Test the entire program

Test each program block individually

Halt test run (soft key only appears once you have
started the test run)