Touch Probe Cycles: Automatic Measurement of Workpiece Misalignment

14.6 SET BA

SIC R

O

T

A

TION (Cy

c

le

404, DIN/ISO: G404)

14.6 SET BASIC ROTATION

(Cycle 404, DIN/ISO: G404)

Cycle run

With Touch Probe Cycle 404, you can set any basic rotation
automatically during program run. This cycle is intended primarily for
resetting a previous basic rotation.

Cycle parameters

U

Preset value for basic rotation:

Angular value at

which the basic rotation is to be set. Input range:
-360.000 to 360.000

U

Number in table

Q305: Enter the number in the

preset/datum table in which the TNC is to save the
defined basic rotation. Input range: 0 to 2999

Example: NC blocks

5 TCH PROBE 404 BASIC ROTATION

Q307=+0

;PRESET BASIC ROTATION

Q305=1

;NO. IN TABLE