HEIDENHAIN iTNC 530 (340 49x-05) Cycle programming User Manual

Page 360

Advertising
background image

360

Touch Probe Cycles: Automatic Datum Setting

15.8 D

A

TUM FR

OM OUTSIDE OF CORNER (Cy

c

le 414, DIN/ISO: G414)

U

Probe in TS axis

Q381: Specify whether the TNC

should also set the datum in the touch probe axis:
0: Do not set datum in the touch probe axis
1: Set datum in the touch probe axis

U

Probe TS axis: Coord. 1st axis

Q382 (absolute):

Coordinate of the probe point in the reference axis of
the working plane at which point the datum is to be
set in the touch probe axis. Only effective if Q381 =
1. Input range -99999.9999 to 99999.9999

U

Probe TS axis: Coord. 2nd axis

Q383 (absolute):

Coordinate of the probe point in the minor axis of the
working plane at which point the datum is to be set in
the touch probe axis. Only effective if Q381 = 1. Input
range -99999.9999 to 99999.9999

U

Probe TS axis: Coord. 3rd axis

Q384 (absolute):

Coordinate of the probe point in the touch probe axis
at which point the datum is to be set in the touch
probe axis. Only effective if Q381 = 1. Input range
-99999.9999 to 99999.9999

U

New datum in TS axis

Q333 (absolute): Coordinate in

the touch probe axis at which the TNC should set the
datum. Default setting = 0. Input range: -99999.9999
to 99999.9999

Example: NC blocks

5 TCH PROBE 414 DATUM INSIDE CORNER

Q263=+37

;1ST POINT 1ST AXIS

Q264=+7

;1ST POINT 2ND AXIS

Q326=50

;SPACING IN 1ST AXIS

Q296=+95

;3RD POINT 1ST AXIS

Q297=+25

;3RD POINT 2ND AXIS

Q327=45

;SPACING IN 2ND AXIS

Q261=-5

;MEASURING HEIGHT

Q320=0

;SETUP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q304=0

;BASIC ROTATION

Q305=7

;NO. IN TABLE

Q331=+0

;DATUM

Q332=+0

;DATUM

Q303=+1

;MEAS. VALUE TRANSFER

Q381=1

;PROBE IN TS AXIS

Q382=+85

;1ST CO. FOR TS AXIS

Q383=+50

;2ND CO. FOR TS AXIS

Q384=+0

;3RD CO. FOR TS AXIS

Q333=+1

;DATUM

Advertising