Delete modal program information: m142, Delete basic rotation: m143 – HEIDENHAIN iTNC 530 (340 49x-05) ISO programming User Manual

Page 316

Advertising
background image

316

Programming: Miscellaneous Functions

1

0

.4 Miscellaneous F

unctions f

o

r Cont

our

ing Beha

vior

Delete modal program information: M142

Standard behavior

The TNC resets modal program information in the following situations:

„

Select a new program

„

Execute a miscellaneous function M2, M30, or an N99999999 %....
block (depending on MP7300)

„

Defining cycles for basic behavior with a new value

Behavior with M142

All modal program information except for basic rotation, 3-D rotation
and Q parameters is reset.

Effect

M142 is effective only in the block in which it is programmed.

M142 becomes effective at the start of the block.

Delete basic rotation: M143

Standard behavior

The basic rotation remains in effect until it is reset or is overwritten
with a new value.

Behavior with M143

The TNC erases a programmed basic rotation from the NC program.

Effect

M143 is effective only in the block in which it is programmed.

M143 becomes effective at the start of the block.

The function M142 is not permitted during mid-program
startup.

The function M143 is not permitted during mid-program
startup.