Manual Operation and Setup

14.8 Compensating W

o

rk

piece Misalignment with a 3-D T

o

uc

h Pr

obe

Basic rotation using 2 points:

U

Select the probe function by pressing the PROBING

ROT soft key

U

Position the touch probe at a position near the first

touch point

U

Select the probe direction perpendicular to the angle

reference axis: Select the axis by soft key

U

To probe the workpiece, press the machine START

button

U

Position the touch probe at a position near the second

touch point

U

To probe the workpiece, press the machine START

button. The TNC determines the basic rotation and
displays the angle after the dialog Rotation angle =

Saving the basic rotation in the preset table

U

After the probing process, enter the preset number in which the
TNC is to save the active basic rotation in the Number in table:
input box

U

Press the ENTRY IN PRESET TABLE soft key to save the basic
rotation in the preset table

Saving the basic rotation in the pallet preset table

U

After the probing process, enter the preset number in which the
TNC is to save the active basic rotation in the Number in table:
input box

U

Press the ENTRY IN PALLET PRES. TAB. soft key to save the basic
rotation in the preset table

The TNC shows an active pallet preset in the additional status display
(see “General pallet information (PAL tab)” on page 79).

In order to store a basic rotation in the pallet preset table,
you must activate a zero preset before probing. A zero
preset consists of the entry 0 in all axes of the preset
table!