HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual

Page 364

Advertising
background image

364

Touch Probe Cycles: Automatic Datum Setting

15.2 SL

O

T

CENTER REF PT (Cy

c

le

408, DIN/ISO:

G408, FCL

3

F

u

nction)

Probe in TS axis

Q381: Specify whether the TNC

should also set the datum in the touch probe axis:
0: Do not set the datum in the touch probe axis
1: Set the datum in the touch probe axis

Probe TS axis: Coord. 1st axis

Q382 (absolute):

Coordinate of the probe point in the reference axis of
the working plane at which point the datum is to be
set in the touch probe axis. Only effective if Q381 =
1. Input range -99999.9999 to 99999.9999

Probe TS axis: Coord. 2nd axis

Q383 (absolute):

Coordinate of the probe point in the minor axis of the
working plane at which point the datum is to be set in
the touch probe axis. Only effective if Q381 = 1. Input
range -99999.9999 to 99999.9999

Probe TS axis: Coord. 3rd axis

Q384 (absolute):

Coordinate of the probe point in the touch probe axis,
at which point the datum is to be set in the touch
probe axis. Only effective if Q381 = 1. Input range
-99999.9999 to 99999.9999

New datum in TS axis

Q333 (absolute): Coordinate in

the touch probe axis at which the TNC should set the
datum. Default setting = 0. Input range -99999.9999
to 99999.9999

Beispiel: NC blocks

5 TCH PROBE 408 SLOT CENTER REF PT

Q321=+50

;CENTER IN 1ST AXIS

Q322=+50

;CENTER IN 2ND AXIS

Q311=25

;SLOT WIDTH

Q272=1

;MEASURING AXIS

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q305=10

;NO. IN TABLE

Q405=+0

;DATUM

Q303=+1

;MEAS. VALUE TRANSFER

Q381=1

;PROBE IN TS AXIS

Q382=+85

;1ST CO. FOR TS AXIS

Q383=+50

;2ND CO. FOR TS AXIS

Q384=+0

;3RD CO. FOR TS AXIS

Q333=+1

;DATUM

Advertising