429

16.6 MEA

S

URE CIR

C

LE OUTSIDE (Cy

c

le 422, DIN/ISO:

G422)

Cycle parameters

Center in 1st axis

Q273 (absolute): Center of the

stud in the reference axis of the working plane. Input
range -99999.9999 to 99999.9999

Center in 2nd axis

Q274 (absolute): Center of the

stud in the minor axis of the working plane. Input
range -99999.9999 to 99999.9999

Nominal diameter

Q262: Enter the diameter of the

stud. Input range 0 to 99999.9999

Starting angle

Q325 (absolute): Angle between the

reference axis of the working plane and the first touch
point. Input range -360.0000 to 360.0000

Stepping angle

Q247 (incremental): Angle between

two measuring points. The algebraic sign of the
stepping angle determines the direction of rotation
(negative = clockwise). If you wish to probe a circular
arc instead of a complete circle, then program the
stepping angle to be less than 90°. Input range -
120.0000 to 120.0000

X

Y

Q325

Q247

Q278

Q262

Q277

Q274

±Q280

Q273

±Q279

MP6140

+

Q320