New functions of software 340 56x-02 – HEIDENHAIN TNC 620 (340 56x-02) Cycle programming User Manual

Page 8

Advertising
background image

8

New F

u

nctions of Sof

tw

a

re

340

56x

-02

New Functions of Software 340 56x-02

„

The PATTERN DEF function for defining patterns was introduced (see
“Pattern Definition PATTERN DEF” on page 44)

„

The SEL PATTERN function makes it possible to select point tables
(see “Selecting a point table in the program” on page 54)

„

With the CYCL CALL PAT function, cycles can now be run in
connection with point tables (see “Calling a cycle in connection with
point tables” on page 55)

„

The DECLARE CONTOUR function can now also define the depth of the
contour (see “Entering a simple contour formula” on page 223)

„

New machining cycle for single-fluted deep-hole drilling (see
“SINGLE-LIP D.H.DRLNG (Cycle 241, DIN/ISO: G241, Advanced
Programming Features Software Option)” on page 84)

„

The new fixed cycles 251 to 257 were introduced for milling
pockets, studs and slots (see “Overview” on page 126)

„

Touch Probe Cycle 412: Additional parameter Q365 "type of
traverse" (see “DATUM FROM INSIDE OF CIRCLE (Cycle 412,
DIN/ISO: G412)” on page 328))

„

Touch Probe Cycle 413: Additional parameter Q365 "type of
traverse" (see “DATUM FROM OUTSIDE OF CIRCLE (Cycle 413,
DIN/ISO: G413)” on page 332))

„

Touch Probe Cycle 416: Additional parameter Q320 (setup
clearance, (see “DATUM CIRCLE CENTER (Cycle 416, DIN/ISO:
G416)” on page 345))

„

Touch Probe Cycle 421: Additional parameter Q365 "type of
traverse" (see “MEASURE HOLE (Cycle 421, DIN/ISO: G421)” on
page 376))

„

Touch Probe Cycle 422: Additional parameter Q365 "type of
traverse" (see “MEAS. CIRCLE OUTSIDE (Cycle 422, DIN/ISO:
G422)” on page 380))

„

Touch Probe Cycle 425 (MEASURE SLOT) was expanded by
parameters Q301 (Move to clearance height) and Q320 (setup
clearance) ((see “MEASURE INSIDE WIDTH (Cycle 425, DIN/ISO:
G425)” on page 392))

„

In the machine operating modes Program Run, Full Sequence and
Program Run, Single Block, datum tables can now also be selected
(STATUS M)

„

The definition of feed rates in fixed cycles can now also include FU
and FZ values

Advertising