Comparison: differences in program run, operation – HEIDENHAIN TNC 620 (73498x-01) ISO programming User Manual

Page 483

Advertising
background image

HEIDENHAIN TNC 620

483

Comparison: Differences in Program Run,
operation

Function

TNC 620

iTNC 530

Arrangement of soft-key rows and soft
keys within the rows

Arrangement of soft-key rows and soft-keys varies depending on the active screen
layout.

Editing of program after program run
was interrupted by switching to the
Single block mode of operation.

The INTERNAL STOP soft key must also
be pressed to cancel the program

Editing is possible right after switching
to the Programming mode of operation

Operating-mode switchover after
program run was interrupted by
switching to the Single block mode of
operation

The INTERNAL STOP soft key must also
be pressed to cancel the program

Switching the operating mode is
allowed

Operating-mode switchover after
program run was interrupted by
switching to the Single block mode of
operation, and canceled by INTERNAL
STOP

on the TNC 620

When you return to the Program Run
mode of operation: Error message
Selected block not addressed

. Use

mid-program startup to select the point
of interruption

Switching the operating mode is
allowed, modal information is saved,
program run can be continued by
pressing NC start

GOTO is used to go to FK sequences
after program run was interrupted there
before switching the operating mode

Error message FK programming:
Undefined starting position

GOTO allowed

Mid-program startup:

„

Behavior after restoring the machine
status

„

The menu for returning must be
selected with the RESTORE
POSITION soft key

„

Menu for returning is selected
automatically

„

Completing positioning for mid-
program startup

„

After position has been reached,
positioning mode must be exited with
the RESTORE POSITION soft key

„

The positioning mode is automatically
exited after the position has been
reached

„

Switching the screen layout for mid-
program startup

„

Only possible, if startup position has
already been approached

„

Possible in all operating states

Error messages

Error messages are still active after the
error has been corrected and must be
acknowledged separately

Error messages are sometimes
acknowledged automatically after the
error has been corrected

Editing Q-parameter contents after
program run was interrupted by
switching to the Single block mode of
operation

The INTERNAL STOP soft key must also
be pressed to cancel the program

Direct editing possible

Manual traverse during program
interruption and with active M118

Function not available

Function available

Advertising