C: tuning, B parameter table – Yaskawa L1000E AC Drive CIMR-LE†A User Manual

Page 166

Advertising
background image

B Parameter Table

166

YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide

b8: Energy Saving

C: Tuning

C parameters are used to adjust the acceleration and deceleration ramps, jerk settings, slip compensation, torque
compensation, and carrier frequency selections.

C1: Acceleration and Deceleration Ramps

No.(Addr.)

Name

Description

Setting

b8-01

(1CCH)

Energy Saving Control
Selection

0: Disabled
1: Enabled

Default: 0
Min: 0
Max: 1

b8-16

(1F8H)

Energy Saving Control
Constant (Ki)

Enter the Energy Saving value (Ki) as specified on the motor name plate. (for
IPM motors only)

Default: 0.10
Min: 0.00
Max: 2.00

b8-17

(1F9H)

Energy Saving Control
Constant (Kt)

Enter the Energy Saving value (Kt) as specified on the motor name plate. (for
IPM motors only)

Default: 1.00
Min: 0.00
Max: 2.00

No.

(Addr.)

Name

Description

Setting

C1-01

(200H)

Acceleration Ramp 1

Sets the ramp to accelerate from 0 to maximum speed.

Default: 1.50 s

<6> <8>

Min: 0.00 s
Max: 600.00 s

<6> <8>

C1-02

(201H)

Deceleration Ramp 1

Sets the ramp to decelerate from maximum speed to 0.

C1-03

(202H)

Acceleration Ramp 2

Sets the ramp to accelerate from 0 to maximum speed.

C1-04

(203H)

Deceleration Ramp 2

Sets the ramp to decelerate from maximum speed to 0.

C1-05

(204H)

Acceleration Ramp 3 (Motor
2 Accel Time 1)

Sets the ramp to accelerate from 0 to maximum speed.

C1-06

(205H)

Deceleration Ramp 3 (Motor
2 Decel Time 1)

Sets the ramp to decelerate from maximum speed to 0.

Default: 1.50 s

<6> <8>

Min: 0.00 s
Max: 600.00 s

<6> <8>

C1-07

(206H)

Acceleration Ramp 4 (Motor
2 Accel Time 2)

Sets the ramp to accelerate from 0 to maximum speed.

C1-08

(207H)

Deceleration Ramp 4 (Motor
2 Decel Time 2)

Sets the ramp to decelerate from maximum speed to 0.

C1-09

(208H)

Fast Stop Ramp

Sets the ramp for the Fast Stop function.

C1-10

(209H)

Accel/Decel Setting
Resolution

0: 0.01 s unit
1: 0.1 s unit

Default: 0
Min: 0
Max: 1

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

Advertising