3.1 Main Circuit Wiring

3-9

3

Wiring and Connection

(4) Power Supply Capacities and Power Losses

The following table gives the power capacities and power losses of the SERVOPACK.

∗1. For the optional JUSP-RA05-E regenerative resistor unit.

∗2. For the optional JUSP-RA18-E regenerative resistor unit

Note 1. SGDV-R70F, -R90F, -2R1F, -2R8F, -R70A, -R90A, -1R6A, and -2R8A SERVOPACKs do not have built-in

regenerative resistors. If the regenerative energy exceeds the specified value, connect an external regenerative

resistor (optional).

2. SGDV-550A and -260D SERVOPACKs do not have built-in regenerative resistors. Be sure to connect a regener-

ative resistor unit (optional) or an external regenerative resistor (optional). For selection details, refer to 3.7
Regenerative Resistors Connections
.

3. Regenerative resistor power losses are allowable losses. Take the following action if the actual power loss

exceeds the allowable power loss.

• Remove the lead or short bar that is short-circuiting the SERVOPACK main circuit terminal B2 and B3.

(SGDV-3R8A, -5R5A, -7R6A, -120A, -180A, -200A, -330A, or 400-V class SERVOPACKs.)

• Install an external regenerative resistor (optional). For selection details, refer to 3.7 Regenerative Resistors

Connections.

Main Circuit

Power

Supply

Maximum

Applicable

Motor

Capacity

[kW]

SERVO-

PACK

Model

SGDV-

Power Sup-

ply Capacity

per SERVO-

PACK

[kVA]

Output

Current

[Arms]

Main

Circuit

Power

Loss

[W]

Regener-

ative

Resistor

Power

Loss [W]

Control

Circuit

Power

Loss

[W]

Total

Power

Loss

[W]

Single-phase,

100-V

0.05 R70F

0.2

0.66

5.4

17

22.4

0.1 R90F

0.3

0.91

7.8

24.8

0.2 2R1F

0.7

2.1

14.4

31.4

0.4 2R8F

1.4

2.8

25.6

42.6

Three-phase,

200-V

0.05

R70A

0.2

0.66

5.1

17

22.1

0.1

R90A

0.3

0.91

7.3

24.3

0.2

1R6A

0.6

1.6

13.5

30.5

0.4

2R8A

1

2.8

24.0

41.0

0.5

3R8A

1.4

3.8

20.1

8

45.1

0.75

5R5A

1.6

5.5

43.8

68.8

1.0

7R6A

2.3

7.6

53.6

78.6

1.5

120A

3.2

11.6

65.8

10

22

97.8

2.0

180A

4

18.5

111.9

16

149.9

3.0

200A

5.9

19.6

113.8

161.4

5.0

330A

7.5

32.9

263.7

36

27

326.7

7.5

550A

14.6

54.7

357.8

(350)

*1

33

390.8

Three-phase,

400-V

0.5

1R9D

1.1

1.9

24.6

14

21

59.6

1.0

3R5D

2.3

3.5

46.1

81.1

1.5

5R4D

3.5

5.4

71.3

106.3

2.0

8R4D

4.5

8.4

77.9

28

25

130.9

3.0

120D

7.1

11.9

108.7

161.7

5.0

170D

11.7

16.5

161.1

36

24

221.1

7.5

260D

14.4

25.7

218.6

(180)

*2

27

245.6

Advertising