Main G-Force Troubleshooting Guide

12

April 5, 2006

Document #300116 Rev. A

Heart Rate

Complaint: Goes very high initially

Probable Cause: Corrupt software. Return console for software update.

Complaint: Chest Strap won’t pick up

Probable Cause: Customer using non Polar compatible chest strap

Complaint: Contact HR Handles will not work

Potential Cause: It may take as long as 15 seconds for the HR to display for

some people. This can be affected by low heart rates, dry
hands, individuals with a weak electrical signal. The flashing Hr
sign may go to zero, but it is still trying to acquire HR.


Potential Cause: The customer must place their hands on the grip such that the

metal portion of the upper sensor lies across the palm as in the
picture.