DVI 201 Tx/Rx • Installation and Operation

Installation and Operation, cont’d

2-24

DVI 201 Tx/Rx • Installation and Operation

2-25

Terminating shielded cable

N

The transmitter and receiver pair works with unshielded

twisted pair (UTP) or shielded twisted pair (STP) cables;

but, to ensure FCC Class A and CE compliance, STP

cables are recommended.

The Tx/Rx includes four shielded RJ-45 connectors and a length

of self-adhesive shielded tape that you can use to make the STP

cables that connect the transmitter and receiver.

N

Extron supplies the connectors and the shielded tape.

You must supply the CAT 5, 5e, or 6 STP cable.

Terminate the STP cable as follows:
1

.

Peel back the cable shielding (figure 2-21) from the

end of the cable the length of the RJ-45 connector body

(approximately 7/8" [2.2 cm]) and fold it back.

Peel back shield and
fold back.

Figure 2-21 — Peeling back the cable shielding

2

.

Cut away and discard the clear cellophane inner wrapper

from the end of the cable back to the folded-over cable

shielding.

3

.

Peel the backing off the self-adhesive shielded aluminum

tape and wrap it around the folded-over cable shielding,

slightly overlapping

the beginning of the tape

(figure 2-22).

Aluminum Tape

Wrap tape around folded foil shielding.
Slightly overlap.
Cut and save the excess tape

for other connectors.

Figure 2-22 — Wrapping the shielded tape

4

.

Cut the unused portion of the shielded tape and retain for

shielding other RJ-45 connectors.

5

.

Crimp the RJ-45 cable in the normal manner, folding the

tangs at the end of the connector over the shielded tape

(figure 2-23).

Crimped Connector

Figure 2-23 — Crimped RJ-45 connector

Power supply wiring

N

• Only one power supply is required. A single power

supply connected to either unit in the pair powers

both units.

A single power supply is included with systems

packaged as a pair.

A power supply is also included with each

individually-packaged transmitter.

Figure 2-24 shows how to wire the connector.

C

Power supply voltage polarity is critical. Incorrect

voltage polarity can damage the power supply and

the transmitter or receiver. Identify the power cord

negative lead by the ridges on the side of the cord

(figure 2-24).

To verify the polarity before connection, plug in the power

supply with no load and check the output with a voltmeter.

Power Supply

Output

Cord

SECTION A–A

Ridges

Smooth

A

A

NOTE

Captive Screw

Connector

Decora units have a
shorter connector,
without the tie wrap.

Tie Wrap

Ferrite Bead

DC Power Cord
(between power supply
and DVI unit
power connector)

3

5

Figure 2-24 — Power connector wiring

W

The two power cord wires must be kept separate

while the power supply is plugged in. Remove

power before wiring.