Mounting the Unit

C

Installation and service must be performed by

authorized personnel only.

The 1" high, quarter-rack width transceiver can be placed on

a tabletop, mounted on a rack shelf, mounted under a desk or

tabletop, or mounted on a projector bracket.

Tabletop placement

Affix the four included rubber feet to the bottom of the unit and

place it in any convenient location.

Rack mounting

UL requirements

The following Underwriters Laboratories (UL) requirements

pertain to the installation of the FOX HD-SDI transmitter or

receiver into a rack (figure 2-1).
1

.

Elevated operating ambient temperature

— If installed in

a closed or multi-unit rack assembly, the operating ambient

temperature of the rack environment may be greater

than room ambient. Therefore, consider installing the
equipment in an environment compatible with the +122 °F
(50 °C) maximum ambient temperature (Tma) specified by

Extron.

2

.

Reduced air flow

— Installation of the equipment in a rack

should be such that the amount of air flow required for

safe operation of the equipment is not compromised.

3

.

Mechanical loading

— Mounting of the equipment in

the rack should be such that a hazardous condition is not

achieved due to uneven mechanical loading.

4

.

Circuit overloading

— Consideration should be given to

the connection of the equipment to the supply circuit and

the effect that overloading of the circuits might have on

overcurrent protection and supply wiring. Appropriate

consideration of equipment nameplate ratings should be

used when addressing this concern.

5

.

Reliable earthing (grounding)

— Reliable earthing

of rack-mounted equipment should be maintained.

Particular attention should be given to supply connections

other than direct connections to the branch circuit (such as

the use of power strips).

Mounting instructions

For optional rack mounting, mount the transceiver on any of the

following rack shelves:
• RSF 123 3.5" deep 1U VersaTools

®

rack shelf kit

(part #60-190-20) (figure 2-1)

• RSB 123 3.5" deep 1U VersaTools rack shelf (part #60-604-20)
• RSU 126 6" deep 1U universal rack shelf kit

(part #60-190-10)

• RSB 126 6" deep 1U basic rack shelf (part #60-604-10)
• RSU 129 9.5" deep 1U universal rack shelf kit

(part #60-190-01) (figure 2-2 on the next page)

• RSB 129 9.5" deep 1U basic rack shelf (part #60-604-01)

(2) 4-40 x 3/16"
Screws

Use 2 mounting holes on
opposite corners.

VersaTools Rack Shelf

1/4 Rack Width Front
False Faceplate

Figure 2-1 — Mounting the transceiver on a
VersaTools rack shelf

On the non-VersaTools rack shelves, the transceiver unit can be

mounted in the front or the rear of the rack.
1

.

If installed, remove the feet from the bottom of the unit.

2

.

Mount the unit on the shelf, using two 4-40 x 3/16" screws

in opposite (diagonal) corners to secure the unit to the

shelf.

3

.

Install false faceplate(s) or other unit(s) to the rack shelf.

4

.

Insert the shelf into the rack, aligning the holes in the shelf

with those of the rack.