Check that the equipment to be connected is switch off. When the
equipment to be used is switched on, it will operate suddenly, and injuries
or accidents may be caused.

4.

Switch on the equipment output indicator light will glitter (light). In case of overload
operation or when trouble occurs for the equipment being used, the output indicator light
(green) will go out, the overload indicator light (red) will light continuously, and no power
will be put out. At this time, the engine will not stop, so that the engine must be stopped
by setting the respective engine switch to STOP.

Fig 13

13.1

When overload or short circuited, overload indicator will illuminate (red)

13.2

Normal: output indicator will illuminate

When equipment requires a large starting power, the overload indicator
lights (red) and the output indicator light (green) may light together for a
short time, but this is no abnormality. After start of the equipment, the
overload indicator light (red) will go out and the output indicator light
(green) will stay lit.

AC

Electric
lamps

Power tools

Electromotor

DC battery

Power factor

1

0.8-0.9

0.4-0.7
(Efficiency
0.85)

POW4820(SC)

1900

1520

760

Rated voltage 12V
Rated current 6A(for
Canada) 8A (except for
Canada)

POW4830(SC)

2500

2000

1000

8.6

DC applications

For charging 12V automotive batteries:

Idling
voltage (V)

Loading voltage
(V)

Loading
current (A)

Opening the smart throttle

22

12

6

Closing the smart throttle

27

13

8.5

DC Max. output power

37

13.5

8.5

The generator cannot sense a sensibility load with the same power which the manual
indicates. It only can sense 40%-70% power which the manual indicates.
Example:

Model

POW4820(SC)

POW4830(SC)

Generator rated output

1900VA

2500VA

Frequency

Power factor

AC

1.0

1800W

2300W

0.4~0.75

720W~1350W

920W ~ 1725W

DC

96W
12V/8A

§ When using the DC output, turn Smart Throttle to the OFF position. The DC current will be

below 5A if turning on the Smart Throttle without AC current output.

§ When charging batteries, person must be present to monitor the voltage. Stop charging

when the voltage of the batteries is above 16V. Or it may cause battery explosion,
resulting in serious injury or death.