No yes no no yes yes – Powerplus POW4820 POWER G ENERATOR 2000W DIGITAL EN User Manual

Page 17

Advertising
background image

POW4820-POW4830(SC)

EN

Copyright © 2010 VARO

P a g e

| 17

www.varo.com







§ Shake the generator several times to make the float rise if the generator cannot start after

adding oil for the first time and the oil alarm indicator stays on when pulling the starting
grip.

§ Make sure there is no spilled fuel around the spark plug. Spilled fuel may ignite.
§ If the engine still doesn’t start, have the generator repaired by a licensed repair person.
Inspection:
§ Remove the spark plug rubber boot and clean any dirt from around the spark plug.
§ Remove the spark plug and place it in the spark plug rubber boot.
§ Connect the side electrode of the spark plug to the metal parts of the engine.
§ Pull the starting cord. A spark could jump across the gap.
The equipment that connects generator doesn’t start:





















Spark plug works or
not?

Yes

Replace

spark

plug.

Send the generator
to an authorized
dealer

No

No

Is the output
indicator on?

Is the overload
indicator on?

Does

the

electrical
equipment work
when

plugged

in directly?

Send

the

generator

to

an

authorized dealer.

Restart after turning off the
overload indicator.

Send

the

generator

to

an

authorized dealer.

Replace the electric equipment.
Repair the electric equipment.

No

Yes

No

No

Yes

Yes

Advertising