8generator use – Powerplus POW4820 POWER G ENERATOR 2000W DIGITAL EN User Manual

Page 8

Advertising
background image

POW4820-POW4830(SC)

EN

Copyright © 2010 VARO

P a g e

| 8

www.varo.com

7.3

Check the air cleaner.

Check the air cleaner element to be sure it is clean and in good condition.
1.

Loosen the cover screw and remove the left side maintenance cover.

2.

Press the latch tab on the top of the air cleaner body, remove the air cleaner cover, and
check the element.

3.

Clean or replace the element if necessary.

Fig 6

6.1

Maintenance cover

6.2

Air filter body

6.3

Air filter cover

6.4

Air filter element

Never run the engine without the air cleaner. Rapid engine wear will result from contaminants,
such as dust and dirt, being drawn through the carburettor, into the engine.

8

GENERATOR USE

8.1

Starting the engine

Before starting the engine, disconnect any load from the DC receptacle.

§ Turn the fuel cap lever fully clockwise to the ON position.

Fig 7

7.1

Air inflow knob

§ Set the fuel valve in the “ON”-position.

Fig 8

8.1

Turn the fuel valve knob to the ON position

§ To start a cold motor shove the choke lever all the way to the left. To restart a hot motor

set the choke lever half-way.

Fig 9

9.1

Choke lever

Choosing the right choke position is the key to starting the motor. You may have to practise a
few times to use the choke correctly .

Fig 10

10.1

Cold

10.2

Warm

10.3

Hot

§ Shove the choke completely to the right to restart a hot motor.
§ Shove the choke to about halfway to restart a warm motor.

A hot motor will not start if there is too much fuel in the cylinder. If this
happens, wait five to ten minutes before trying again. Shove the choke
completely to the right and the motor should start.

§ Set the motor switch in the “ON”-position.

Fig 11

11.1

Engine switch

§ Pull slightly on the start cord until you feel resistance and then yank hard and swiftly.

Fig 12

12.1

Starting grip

Do not let the start cord retract by itself: guide it back by hand.

Hold the carrying handle firmly to prevent the generator from falling over
when you pull the start cord.

§ After the engine starts, allow the engine to run continuously and warm up.

Advertising