PoleVault Systems Installation • Installation — Stage 2

2-10

Stage Two — Install the Wallplates and MLC 104 IP Plus

N

The installation must conform to national and

local electrical codes, and UL requirements.

Refer to the devices’ user manuals for details.

1. Install mud rings

N

These devices can be installed using the supplied

mud ring or a wall box. If installing a box, allow

enough depth for the plate, and the cables. The box

should be at least 2.5" (6.4 cm) deep to

accommodate the connectors and cables.

If a suitable wall box is already installed, follow

step 2 onwards.

a.

Mark the holes for the mud rings.

T

Use a level when marking the holes.

b.

Cut out the material from the marked area.

c.

Insert the mud ring into the opening. The mud ring’s

rear connectors should fit easily into the opening. Bend

over the mud ring doglegs and secure with the screws

provided.

Repeat steps a to c for all the transmitters needing to be

installed.

d.

At the desired location repeat steps a to c for the larger

MLC 104 IP Plus mud ring

Wall

Dogleg

Dogleg
Screw

Surface Mounting
Hole

Equipment Mounting
Holes

NOTE

Rotate the dogleg out of
the way to insert the
mud ring into the wall.

Extron
Mud Ring

1d

Features for mud ring installation