Optional accessory installation - ppc 25, Connect sensor to paging speaker, Connect sensor to the ppc 25 – Extron electronic PoleVault Systems PVS 400 User Manual

Page 42: Connect the ppc 25 to the switcher, Optional accessory installation — ppc 25

Advertising
background image

PoleVault Systems Installation • Optional Accessory Installation

2-30

Optional Accessory Installation — PPC 25

1. Connect sensor to paging speaker

a.

Open the top of the Priority Page Sensor.

b.

Loop (only) one of the Paging speaker wire leads around

the top (open) part of the Sensor. Either speaker wire

will work. Leave the other speaker wire connected

directly to the Paging speaker. Polarity need not be

observed.

• For a 25 V or 70V system — wrap 5 to 8 loops.

• For a 4/8 ohm system — wrap 2 to 4 loops.

c.

Close the top of the Priority Page Sensor.

2. Connect sensor to the PPC 25

a.

Cut an 18" section from the unterminated end of the

supplied blue sensor cable, for use in step 3.

b.

Connect the bare wire end of the supplied blue sensor

cable to the 2-pole captive screw connector on the Page

Sensor. Polarity need not be observed.

c.

Route the connector end of the sensor cable to the PPC 25

Controller and plug it into the Paging Sensor port.

3. Connect the PPC 25 to the switcher

a

. Connect the 18" cable made in step 2a to the Relay Out

port on the PPC 25 Controller and to the mute and

ground pins on the PVS 204SA Vol/Mute port. Polarity

need not be observed.

b

. Use the included power supply cable assembly

(PN 27-576-01LF) to power the PPC 25 from the

PVS 204SA power supply. The PPC 25 must be mounted

near the PVS 204SA and its power supply.

Open the
Sensor

Ceiling Mounted
Paging Speaker

Page
Sensor

From
PA system

To Priority
Page Controller

1a

Open the sensor and

1b

Loop wire

around the sensor

PO

WE

R

C

NO

PAG

ING

RE

LAY

DE

LAY

SE

NS

ITIV

ITY

12V
0.2

A

MA

X

ON

1

2

L

R

AUX

/MIX

IN

DO

NO

T G

RO

UN

D

OR

SH

OR

T

SP

EA

KE

R O

UT

PU

TS

!

1B

1A

I
N

P
U

T
S

O

U

T
P
U

T
S

2B

2A

3B

3A

RS-232

ML

C/IR

DC

VO

L

4/8 O

hm

s

AM

PLIFIED OUTPUTS

VOL

/MUTE

Tx

A

B

C

Rx

IR

12V

10V

PO

WER

12V

3A

M

AX

US

LIS

TED

17

TT

AU

DIO/V

IDEO

APP

AR

ATU

S

®

RG

B

VID

EO

RG

B

VID

EO

Ceiling Mounted
Paging Speaker

Page
Sensor

From Classroom
Paging System

Relay
Output

Remote
Vol/Mute
Control

Extron
PPC 25

Priority Page
Controller

Extron
PVS 204SA

Twisted Pair
Switcher

L

R

RS-232 MLC/IR

DC VOL

4/8

Ohms

AMPLIFIED OUTPUTS

VOL/MUTE

Tx

A B C

Rx IR

12V

10V

Mute
(center)

PVS 204SA
rear panel

Ground
(right)

PV SI 3C LP

Ceiling
Speakers

Ple

nu

m R

ate

d U

L 2

043

Su

itab

le f

or

Us

e in

Ai

r-H

and

ling

S

pac

es

The example below is the installation of the optional accessory Priority Page Controller and Sensor (PPC 25).

The Priority Page Controller momentarily silences classroom audio whenever a page is made from a public address

(PA) system.
For detailed information, refer to the PPC 25 Installation Instructions, supplied with the device.

N

Follow all local fire and safety code requirements for installation and anchoring.

3a

Connect the relay to the switcher

Advertising