Maintenance and Modifications, cont’d

HSA 822 Hideaway

®

Enclosure • Maintenance and Modifications

HSA 822 Hideaway

®

Enclosure • Maintenance and Modifications

3-12

Adjusting the Top Surface

The top lifting panel of the HSA 822 can be adjusted to raise or
lower its level flush with the flange. It can also be adjusted to
ensure that the lifting panel is horizontal and not tipped.

Adjusting the height of the top surface

You may be able to adjust the height of the top lifting
panel without removing the HSA 822 from the table. If
you can reach the height adjustment lock screw slots
(figure 3-7) in the side of the enclosure with a long
Phillips-head screwdriver, you should not need to remove
the HSA from the table.

Height Adjustment

Locking Screw Slots

CO

MPU

TER

INP

UT

SEL

ECT

AU

DIO

Figure 3-7 — Height adjustment locking screw slots

Raise or lower the lifting panel flush with the flange as follows:

1

.

If you cannot access the height adjustment locking screw
slots in the side of the HSA enclosure, remove the surface
mount enclosure from the table. See “Removing and
Replacing the Enclosure”, steps 1 through 9. Place the
enclosure on its side on a horizontal surface. To protect
the finish, place the enclosure on a soft cloth.

2

.

If necessary, close and latch the top panel.

3

.

Slightly loosen the two locking screws (figure 3-8).

Loosen
locking
screws.

Adjustment
Screw

Figure 3-8 — Height adjustment screw location

4

.

Turn the height adjustment screw counter clockwise to
raise the lifting plate or clockwise to lower the plate
(figure 3-8).

5

.

Tighten the two locking screws that you loosened in step 3.

6

.

If removed, reinstall the surface mount enclosure in the
table. See “Removing and Replacing the Enclosure”, steps
12

through 18.

3-13