Digital music amplifiers, Main pcb jumpers, Addressable dual muting system – El Paso Chile Company DMS 3080-80 User Manual

Page 17: Direct muting wiring, Mute jumpers default setting table

Advertising
background image

PAGE 17

SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE

DMS3040/3080/3120

ADDRESSABLE DUAL MUTING SYSTEM

DIRECT MUTING - Direct Muting may be accomplished by short-
ing the MUTE 1 and MUTE 2 Terminals to the G Terminal through
an external switch. Each time the Muting Switch is closed the cor-
responding MUTE BUSS is activated.

Fig. 17 - Direct Muting Terminals and Diagram

DIRECT MUTING

WIRING

3120 M1 - M2 01

G

M2

M1 RVC

GROUND

MUTE 1

MUTE 2

MASTER
REMOTE
VOLUME

RVC

MUTING SWITCH M 2

MUTING SWITCH M 1

10

31

MUTE-2

DELAY

Signal

Level

Program

gradually

restored

2-3

sec.

Mute terminals

opened

time

DMS mutfunct 01

Program

Attenuation

60 dB

MUTE 1

Terminals

shorted

Fig. 17B - M 1 Function Timing Diagram

MUTING TIMING - The MUTING is preset for -60 db Attenuation.
When MUTE 1 or 2 are activated the MUTE BUSS is instanta-
neously Switched-ON. When the Muting is deactivated the pro-
gram source is gradually restored.

MUTE 1 (M1) = TIMING PRESET 2-3 SECONDS
MUTE 2 (M2) = TIMING ADJUSTABLE 3-30 SECONDS
MUTE 2 DELAY = USE REAR PANEL CONTROL Reference 31

INSTALLATION AND WIRING

MUTE JUMPERS DEFAULT SETTING TABLE

SW206

VOX RELAY -

MUTE 1 - MUTE 2

M1

SW216

TEL IN -

MUTE 1 - MUTE 2 - OFF

OFF

SW217

INPUT 4/AUX 1 -

MUTE 1 - MUTE 2 - OFF

M1

SW218

INPUT 3 -

MUTE 1 - MUTE 2 - OFF

OFF

SW219

INPUT 2 -

MUTE 1 - MUTE 2 - OFF

OFF

SW220

INPUT 1 -

MUTE 1 - MUTE 2 - OFF

OFF

SW222

MODULE -

MUTE 1 - MUTE 2 - OFF

OFF

SW223

INPUT 5/AUX 2 -

MUTE 1 - MUTE 2 - OFF

M1

SW227

CHIME TRIGGER -

MUTE 1 - MUTE 2

M1

JUMPER

JUMPER

FUNCTION

FACTORY

FACTORY

ID NO.

REFERENCE

DESCRIPTION

SETTING

SETTING

MAIN PCB JUMPERS

DUAL MUTING SYSTEM - The Amplifier is equipped with a DUAL
noiseless, fast acting Logic MUTING Switching System. When any
of the INPUTS are activated and a Signal is present on a given
INPUT and either VOX 1 or VOX 2 or BOTH are Switched-ON
(using internal Jumpers) then the MUTE 1 or MUTE 2 BUSS or
BOTH are ACTIVE. If any of the INPUTS have the MUTE 1 or
MUTE 2 Switched-ON (by Internal Jumpers) then the INPUT (or
INPUTS) will be MUTED according to the Jumpers Setting. Once
the SIGNAL-ON on the ACTIVE INPUT is terminated the normal
functions are automatically restored on all muted inputs.

ACCESS TO MUTE JUMPERS
REFER TO JUMPERS AND SWITCHES INTERNAL ACCESS.

CAUTION: PRIOR TO PERFORMING THE ABOVE OPERATION
BE SURE TO FOLLOW THE SAFETY NOTES REFERRING TO
THE REMOVAL OF THE AMPLIFIER COVER.

Signal

Level

MUTE 2

Terminals

shorted

Program

gradually

restored

Adjustable

from

3 to 30

seconds

Mute terminals

opened

time

DMS mutfunct 02

Program

Attenuation

60 dB

Fig. 17C - M 2 Function Timing Diagram

MUTE 2 DELAY - The M 2 Delay can be adjusted by using the
MUTE 2 DELAY CONTROL on the rear panel (reference 31).

PROFESSIONAL AUDIO & SOUND

®

TM

DIGITAL MUSIC SERIES

DIGITAL MUSIC AMPLIFIERS

Advertising