EATON 350 Series Dual Path Mobile Pumps E-PUPI-TS006-E September 2007

Assembly
Front Pump
Assembly

Step 37

Insert a high-pressure relief
valve in the first pressure relief
port. Tighten to 143 n/m
(105.5 lb-ft).

Step 38

Repeat process for other three
pressure relief valves and ports.

Step 39

Assemble a speed sensor: Slide
an O-Ring 4995422-001 on the
straight end of the sensor
(Refer to Item 55, page 5 for
part number), place a washer
16048-077 and snap ring
16120-125 on the plug end of
the sensor.

Step 40

Insert the sensor sub-assembly
in the speed sensor port. Using
snap-ring pliers, work the snap
ring into port until it engages
the snap ring groove.

Assemble the Controller

Step 41

Insert a feedback pin 4999960-
001 through each 17mm hole
on the two controller mounting
faces. Using a 5/16-inch socket,
tighten each feedback pin to
14 n/m (10.3 lb-ft).

Step 42

Insert an M6 x 25mm socket-
head cap screw 114975-025
in each of (6) holes in the
controller housing.

Step 43

Place the controller gasket
5987239-001 over the exposed
ends of the cap screws.

Step 44

Lift the controller housing
toward the controller mounting
face, taking care not to let the
gasket or screws fall.

Step 45

Align the feedback link inside
the controller housing with the
feedback pin extending from the
mounting plate. Tighten the
screws to 14 n/m (10.3 lb-ft).

Displacement Limiters

Step 46

If the pump includes displace-
ment limit ports, insert a
displacement limiting screw
16139-644 in each of the two
larger ports.

Step 47

Install a sealing nut 5996839-
001 over each displacement

limiting screw and tighten to

16 n/m (11.8 lb-ft).

Step 48

Repeat this process for the two
smaller displacement limit ports,
tightening the sealing nuts
5996838-001 to 9 n/m (6.6 lb-ft).

Step 49

Seal unused ports with appro-
priate plugs.