Troubleshooting – Eaton Electrical 350 User Manual

Page 39

Advertising
background image

39

EATON 350 Series Dual Path Mobile Pumps E-PUPI-TS006-E September 2007

Troubleshooting

This fault – logic trouble shooting guide is a diagnostic aid in locating
transmission problems.

Match the transmission symptoms with the problem statements
and follow the action steps shown in the box diagrams. This will
give expedient aid in correcting minor problems eliminating
unnecessary machine down time.

Following the fault - logic diagrams are diagram action comments
of the action steps shown in the diagrams. Where applicable, the
comment number of the statement appears in the action block
of the diagrams.

Recommended Gauge Locations

Fault - Logic Troubleshooting

Charge Pump Suction Port
Tee in line to check Inlet Vacuum

Pressure Ports
Tee in line to check
System Pressure

Auxilliary Port
check Charge Pressure

Drain Port
Tee in line to check
Case Pressure

Gauges Recommended

Inlet vacuum gauge: 2 bar to 1 bar [30 psi to 30 inHg]
System pressure gauge: 700 bar [10,000 psi]
Charge pressure gauge: 0 to 50 bar [0 to 600 psi]
Case pressure gauge: 0 to 25 bar [0 to 300 psi]

1

Inspect

?

Repair

or

Replace

Defective

Action

Step

Comment

Number

Decision

Solution

Symptom:

Explanatory
Diagram