Fault - Logic Troubleshooting

Inspect

Control Valve

Inspect

Servo piston

Repair

or

Replace

Defective

Ok

Ok

Ok

1

4

2

Replace

Pump

Symptom: Neutral Difficult or Impossible to Find

Inspect

External

Control Linkage

Repair

or

Replace

Defective

Defective

Repair

or

Replace

Inspect

Heat

Exchanger

Inspect Heat

Exchanger

Bypass Valve

(If used)

Repair

or

Replace

Defective

Ok

Ok

Ok

7

6

5

Symptom: System Operating Hot

Check

Oil Level in

Reservoir

Fill to

Proper

Level

Defective

Below Level

Repair

or

Replace

Check

System

Pressure

Reduce
System

Load

High

Ok

10

Inspect Charge

Relief Valve

Repair

or

Replace

Defective

Ok

12

Inspect
Charge

Pump

Repair

or

Replace

Defective

14

Inspect Motor

Repair

or

Replace

Defective

Ok

13

Inspect

Inlet

Screen or Filter

Replace

Clogged

Ok

9

Check

Charge

Pressure

11

Low

Ok

Ok

Replace

Pump & Motor

Inspect

Bypass Valve

(If used)

Repair

or

Replace

Defective

Ok

8