Connecting the psm cables and ac power cords, Connecting the psm cables and ac power cords -6, Fastening the c2rps-chas8 to the rack -6 – Enterasys Networks C2RPS-SYS User Manual

Page 28: Connecting the psm cables and ac, Power cords, Аб б в в, Figure 2-2 fastening the c2rps-chas8 to the rack

Advertising
background image

Connecting the PSM Cables and AC Power Cords

2-6 Installation

Figure 2-2 Fastening the C2RPS-CHAS8 to the Rack

Connecting the PSM Cables and AC

 

Power Cords

The PSMs are connected to the SecureStack Ethernet switch devices using PSM cables. 

To connect the PSMs, proceed as follows:

1.

Connect one end of the PSM cable (shown in 

Figure 2‐3

) to the Redundant Power 

Supply connector on the switch device. Then connect the other end to the Redundant 
Power Supply connector at the rear of the PSM shown in 

Figure 2‐4

 and 

Figure 2‐5

.

2.

Connect a standard AC power cord to the AC input power connector on the PSM 
shown in 

Figure 2‐4

, then plug the AC power cord into the main AC power outlet. 

3.

The green Power LED on the front of the PSM will glow to indicate a successful 
connection. If the LED remains off, proceed as follows:

a.

Check the AC power cord connection at the AC power source and make sure the 
power source is within specification.

b. Check the AC power connection to the PSM.

c.

Swap the AC power cord with a known good one.

d. If the green LED continues to remain off, contact Enterasys Networks. Refer to 

Getting Help

” on page 1‐5 for instructions. Otherwise, go to step 4.

4.

If two or more power supplies are being installed, repeat steps 1 through 3 for each 
PSM.

1 C2RPS-CHAS8 chassis

3 Mounting screws (supplied by user)

2 Rails of 19-inch rack

А

Б

Б

В

В

C2RPS-CHAS8

C2RPS-PSM

Po

w

er

C2RPS-PSM

Po

w

er

C2RPS-PSM

Po

w

er

C2RPS-PSM

Po

w

er

C2RPS-PSM

Po

w

er

C2RPS-PSM

Po

w

er

C2RPS-PSM

Po

w

er

C2RPS-PSM

Po

w

er

Advertising