background image

4. Install a wall control in the wall box

containing the “hot” wire first. Connect
the black wire of the wall control to the
“hot” wire. Securely connect wires with
wire connectors supplied.

5. Connect one black wire of the wall

control to both remaining traveler wires
in the wall box and secure with wire
connector supplied.

4. Connect one black wire of wall control

to the “hot” wire. Securely connect
wires with wire connectors supplied
(Figure 16).

5. Connect one black wire of wall switch

to the “load” (black) wire in wall box.
Securely connect wires with wire
connector supplied.

6. Screw wall control into wall box and

install decorator style faceplate
(included). Leave wall control in “OFF”
mode until fan installation is completed.

7. Refer to page 4 and complete the

ceiling fan installation.

10

Do not connect any neutral (white)
wire to this control. Incorrect wiring
will damage this control.

!

WARNING

EMERSON

®

HI

MED

LOW

FAN OFF

LIGHT

ON

OFF

BLACK

BLK

HOT

FAN/LIGHT
WALL
CONTROL

WALL
BOX

TO LOAD

TO

120VAC

SOURCE

G

RO

UN

D

Figure 16

3-WAY INSTALLATION

(On fan controlled by two different wall
controls) (See Figures 17 and 18.)

1. Disconnect power at circuit breaker or

remove fuse.

2. At all wall box locations remove

faceplates and screws from existing
controls. Pull controls out from wall
boxes and determine which wall box
contains the “hot” lead and which wall
box contains the “load” wire. Also,
identify traveler wires which are
common to both wall boxes.
Disconnect wires from existing controls
only. Do not attempt to disconnect any
wires not already connected to existing
controls.

Installation of Wall

Control

SINGLE-POLE INSTALLATION

(Figure 15)

1. Disconnect power at circuit breaker or

remove fuse.

2. Remove faceplate and screws from

existing wall control. Pull control out
from the wall box. Determine the “hot”
wire and the “load” wire and disconnect
these wires from control. Do not
attempt to disconnect any wires not
already connected to existing control.

3. Before installing wall control, place wall

control in “OFF” mode by pushing
“ON/OFF” switch to the “OFF” position.

EMERSON

®

HI

MED

LOW

FAN OFF

LIGHT

ON

OFF

FAN/LIGHT
WALL CONTROL

HOT

BLK

NEUTRAL

BLACK

GROUND

LOAD

BLACK

REMOTE CONTROL
RECEIVER LOCATED
UNDER THE FAN
HOUSING

Figure 15

3. Before installing wall control, place wall

control in “OFF” mode by pushing
“ON/OFF” switch to the “OFF” position.

Do not connect any neutral (white)
wire to this control. Incorrect wiring
will damage this control.

!

WARNING