3. Pass the outlet box supply wires (black,

white and ground) through the center
hole in the mounting plate and securely
attach the mounting plate to the outlet
box using the screws supplied with the
outlet box (Figure 3).

NOTE: In order for the fan housing to fit
flush with the ceiling, the outlet box
must not protrude below the ceiling.

4. Carefully lift the fan motor assembly

and engage the slot in the motor
bracket with the hook on the mounting
plate so that it is securely suspended
(Figure 4).

The fan must be hung with at least 7'
of clearance from floor to blades
(Figure 2).

!

WARNING

PAN HEAD SCREW
WITH LOCKWASHER

RECEIVER

RECEIVER
BRACKET

CODE
SWITCH

MOUNTING
PLATE

Figure 1

SCREWS (SUPPLIED
WITH OUTLET BOX)

MOUNTING
PLATE

OUTLET BOX

Figure 3

MOUNTING PLATE

HOOK

MOTOR
BRACKET

FAN MOTOR
ASSEMBLY

Figure 4

The outlet box and joist must be
securely mounted and capable of
supporting at least 50 lbs. Use only a
U.L. outlet box listed as “Acceptable
for Fan Support”.

!

WARNING

To reduce the risk of fire, electric
shock, or personal injury, mount fan
to outlet box marked “Acceptable for
Fan Support”, and use screws
supplied with outlet box. Most outlet
boxes commonly used for support of
light fixtures are not acceptable for
fan support and may need to be
replaced. Consult a qualified
electrician if in doubt.

!

WARNING

If you feel that you do not have enough
electrical wiring knowledge or
experience, have your fan installed by a
licensed electrician.

2. Swing the receiver bracket down over

the receiver (Figure 1). Position the
receiver so that the code switch is not
covered by the bracket, then securely
reinstall the pan head screw with
lockwasher (previously removed).