Trouble Shooting

TROUBLE

PROBABLE CAUSE

SUGGESTED REMEDY

1. Fan will not

1. Fuse or circuit breaker

1. Check main and branch circuit fuses

start.

blown.

or circuit breakers.
WARNING: Make sure main power
is turned off.

2. Loose power line

2. Check line power connections to fan.

connections to the fan

3. Fan/Light Wall Control is OFF.

3. Turn ON Fan/Light Wall Control.

4. Code switches in remote control

4. Check that both code switches

receiver and Fan/Light Wall Control

are set in the same positions.

are not set in the same position

2. Fan sounds

1. Screws securing fan blade

1. Check to make sure the

noisy.

flanges to motor hub are

screws which attach the

loose.

blade flanges to the motor
hub are tight.

2. Screws holding blades to

2. Tighten screws securely.

flanges are loose.

3. Fan wobbles

1. Screws securing fan blade

1. Check to be sure screws

flanges to mounting hub

which attach the fan blade

are loose.

flanges to the mounting hub
are tight.

2. Fan blade flanges not

2. Check to be sure that the

seated properly.

fan blade flanges seat firmly
and uniformly on the motor
hub. If flanges are seated
incorrectly, loosen the flange
screws and retighten.

3. Mounting plate and/or

3. Tighten the mounting plate

ceiling outlet box is not

screws to the outlet box,

securely fastened.

and/or secure outlet box.

4. Fan blades out of balance.

4. Interchanging an adjacent

(side-by-side) blade pair can
redistribute the weight and
result in smoother operation.
Or use supplied balancing
kit to balance blades.

WARNING:

FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX

OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.

!

!