Sealey SAC3153B User Manual

Instructions for, Model nos, Fig.1

Advertising
background image

InstructIons for:

COMPRESSOR 150/200ltr BELT dRivE

3.0hp WiTH FRONT CONTROL PANEL

model nos:

SAC3153B/SAC3203B

thank you for purchasing a sealey product. manufactured to a high standard this product will, if used according to these instructions and properly

maintained, give you years of trouble free performance.

1. SAFETY iNSTRUCTiONS

IMPORTANT: PLEASE REAd THESE iNSTRUCTiONS CAREFULLY. NOTE THE SAFE OPERATiONAL REQUiREMENTS, WARNiNGS & CAUTiONS. USE

THE PROdUCT CORRECTLY ANd WiTH CARE FOR THE PURPOSE FOR WHiCH iT iS iNTENdEd. FAiLURE TO dO SO MAY CAUSE dAMAGE OR

PERSONAL iNJURY ANd WiLL iNvALidATE THE WARRANTY. PLEASE KEEP iNSTRUCTiONS SAFE FOR FUTURE USE.

from

pump

to receiver

decompression

tube from switch

fig.1

non return valve

Hose reel tidy

safety valve

Original Language Version

sAc3153B/sAc3203B Issue no: 1 - 01/06/13

© Jack sealey limited 2013

1.1

ELECTRiCAL SAFETY.

WARNiNG! it is the user’s responsibility to read, understand and

comply with the following:

You must check all electrical equipment and appliances to ensure they

are safe before using. You must inspect power supply leads, plugs and all

electrical connections for wear and damage. You must ensure the risk of

electric shock is minimised by the installation of appropriate safety

devices. An rccB (residual current circuit Breaker) should be

incorporated in the main distribution board. We also recommend that an

rcd (residual current device) is used with all electrical products. It is

particularly important to use an rcd together with portable products that

are plugged into an electrical supply not protected by an rccB. If in

doubt consult a professional electrician. You may obtain a residual

current device by contacting your sealey dealer. You must also read

and understand the following instructions concerning electrical safety.

1.1.1 the electricity At Work Act 1989 requires all portable electrical

appliances, if used on business premises, to be tested by a

qualified electrician at least once a year, using a Portable

Appliance tester (PAt).

1.1.2 the

Health & Safety at Work Act 1974 makes owners of

electrical appliances responsible for the safe condition of the

appliance, and the safety of the appliance operator. If in any

doubt about electrical safety, contact a qualified Electrician.

1.1.3 ensure the insulation on all cables and the product itself is safe

before connecting to the mains power supply. see 1.1.1. & 1.1.2.

above and use a Portable Appliance tester (PAt).

1.1.4 ensure that cables are always protected against short circuit and

overload.

1.1.5 regularly inspect power supply, leads, plugs and all electrical

connections for wear and damage, especially power connections,

to ensure that none are loose.

1.1.6 Important: ensure the voltage marked on the product is the same as the

electrical power supply to be used, and check that plugs are fitted with

correct capacity fuse.

1.1.7

dO NOT pull or carry the powered appliance by its power supply

lead or output cables.

1.1.8

dO NOT pull power plugs from sockets by the power cable.

1.1.9

dO NOT use worn or damage leads, plugs or connections.

Immediately replace or have repaired by a qualified electrician.ug.

1.1.10. Model Nos SAC3153B and SAC3203B are supplied with a

flying lead without a plug. Jack Sealey Limited recommend a

16 amp protected supply. When connecting to a 16 amp

protected supply, contact a qualified electrician to ensure

connect to a suitably rated supply.

*Provided a good 230V supply is available and the lead

length is not increased from that supplied, the compressor

may operate from a 13 amp supply. This very much depends

upon the quality of your power supply.

1.2.

Wiring a BS 1363/A UK 3 Pin Plug.

WARNiNG! if in doubt contact a qualified electrician.

a) Connect the GREEN/YELLOW earth wire to the earth

terminal ‘E’.

b) Connect the BROWN live wire to the live terminal ‘L’.

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

d) After wiring, check that there are no bare wires, that

all wires have been correctly connected, that the cable

outer insulation extends beyond the cable restraint and

that the restraint is tight.

double insulated products, which are always marked with

this symbol , are fitted with live (brown) and neutral (blue)

wires only. to rewire, connect the wires as indicated in

diagram.

dO NOT connect either wire to the earth terminal.

We recommend that you discuss the installation of an

industrial round pin plug and socket with your electrician.

iMPORTANT! the use of extension leads to connect these

compressors to the mains is not recommended as the

resulting voltage drop reduces motor, and therefore pump

performance.

RECOMMENdEd

FUSE RATiNG:

*13 AMP

see 1.1.10 for power supply options.